WEBVTT
Language: en-US

1
00:00:10.500 --> 00:00:12.710
<v Jon Lester>Hello and welcome to Buildings of
Tomorrow.

2
00:00:12.819 --> 00:00:16.319
<v Jon Lester>My name is Jon Lester, and today's episode
is another buzzword buster.

3
00:00:16.510 --> 00:00:20.299
<v Jon Lester>So if you haven't heard one of these
episodes from us in the past, they're a

4
00:00:20.299 --> 00:00:25.670
<v Jon Lester>slightly longer format, and basically we
pick one of, you know, the topics that we

5
00:00:25.670 --> 00:00:30.290
<v Jon Lester>discuss within our normal episodes, and we
just have a look at a lot of the terms

6
00:00:30.290 --> 00:00:34.220
<v Jon Lester>and a lot of the phrases that you hear in
the industry and run through with an

7
00:00:34.220 --> 00:00:34.750
<v Jon Lester>expert.

8
00:00:35.189 --> 00:00:40.909
<v Jon Lester>To give a brief description and a
definition of those terms, you know, there are so

9
00:00:40.909 --> 00:00:42.759
<v Jon Lester>many things changing in our industry.

10
00:00:43.310 --> 00:00:47.200
<v Jon Lester>We hear so many terms that perhaps we
don't have a full understanding of what they

11
00:00:47.200 --> 00:00:47.619
<v Jon Lester>mean.

12
00:00:48.040 --> 00:00:50.650
<v Jon Lester>So that is why the buzzword buster exists.

13
00:00:50.919 --> 00:00:53.819
<v Jon Lester>And today we are talking about hydronics.

14
00:00:54.439 --> 00:00:58.330
<v Jon Lester>I'm joined by Chris Coop, who is an expert
in HVAC theory and hydronics.

15
00:00:58.439 --> 00:01:00.139
<v Jon Lester>Chris, thank you very much for joining us.

16
00:01:00.750 --> 00:01:04.379
<v Chris Kopp>Hi John, thank you very much for having me
in this episode.

17
00:01:04.680 --> 00:01:06.620
<v Jon Lester>It is always a pleasure recorded from
home.

18
00:01:06.879 --> 00:01:09.059
<v Jon Lester>We keep charging no matter what happens
outside.

19
00:01:11.800 --> 00:01:12.139
<v Jon Lester>Perfect.

20
00:01:12.279 --> 00:01:15.639
<v Jon Lester>So, so today is a buzzword buster, as I
mentioned, hydronics is the topic.

21
00:01:15.760 --> 00:01:17.029
<v Jon Lester>We're going to dive straight in.

22
00:01:17.120 --> 00:01:19.000
<v Jon Lester>We've, we've taken a slightly different
approach here.

23
00:01:19.040 --> 00:01:22.639
<v Jon Lester>We want to keep it a little organized
because a lot of these terms really do refer

24
00:01:22.639 --> 00:01:24.400
<v Jon Lester>to each other or related to each other.

25
00:01:24.800 --> 00:01:29.919
<v Jon Lester>So we're going to start and run through a
bunch of different hydronic buzzwords.

26
00:01:29.930 --> 00:01:35.279
<v Jon Lester>And where we're going to start, uh, is at
a phrase or an acronym that we hear a lot

27
00:01:35.279 --> 00:01:37.199
<v Jon Lester>in the industry, which is PICV.

28
00:01:37.360 --> 00:01:39.220
<v Jon Lester>Chris, what is PICV?

29
00:01:40.209 --> 00:01:46.830
<v Chris Kopp>So PICV stands for Press Independent
control valve, and

30
00:01:47.089 --> 00:01:50.989
<v Chris Kopp>this already explains a little bit what
it's all about.

31
00:01:51.230 --> 00:01:58.110
<v Chris Kopp>It's an approach for a control valve that
has been launched a couple of years ago

32
00:01:58.370 --> 00:02:03.250
<v Chris Kopp>and is now steadily finding its way into
the applications, into the hydraulic

33
00:02:03.250 --> 00:02:03.889
<v Chris Kopp>circuits.

34
00:02:04.180 --> 00:02:09.779
<v Chris Kopp>And as the name says, it is a control
valve, so that's one key part of it, as in any

35
00:02:09.779 --> 00:02:14.339
<v Chris Kopp>other control valve, but then there is an
additional differential pressure

36
00:02:14.339 --> 00:02:14.880
<v Chris Kopp>controller.

37
00:02:15.639 --> 00:02:21.449
<v Chris Kopp>That basically surrounds the control valve
and makes sure that pressure changes,

38
00:02:21.570 --> 00:02:27.089
<v Chris Kopp>fluctuations in the hydraulic network do
not get to the control valve, so it kind of

39
00:02:27.089 --> 00:02:33.679
<v Chris Kopp>decouples, decouples the control valve
from, The surroundings and by that we can

40
00:02:33.679 --> 00:02:35.270
<v Chris Kopp>achieve more stable control.

41
00:02:35.320 --> 00:02:40.550
<v Chris Kopp>And then the third component is that in
these PICVs, pressure independent control

42
00:02:40.550 --> 00:02:45.000
<v Chris Kopp>valves, we also have the possibility to
limit the maximum flow.

43
00:02:45.080 --> 00:02:50.520
<v Chris Kopp>And by that we are already one big step in
the direction of hydraulic balancing.

44
00:02:51.500 --> 00:02:51.979
<v Jon Lester>Perfect.

45
00:02:52.220 --> 00:02:53.919
<v Jon Lester>And you mentioned there the maximum flow.

46
00:02:53.979 --> 00:02:56.880
<v Jon Lester>That's actually the next word we have on
the list, VMax.

47
00:02:58.100 --> 00:02:58.380
<v Chris Kopp>Yeah.

48
00:02:58.660 --> 00:02:58.899
<v Chris Kopp>OK.

49
00:02:59.059 --> 00:03:05.759
<v Chris Kopp>So, the, the maximum flow is As I said
before, something we can sit on

50
00:03:06.460 --> 00:03:12.800
<v Chris Kopp>such a PICV, it's a manic mechanical
setting, and it ensures that we get The

51
00:03:12.800 --> 00:03:17.520
<v Chris Kopp>right maximum amount of flow, and by that
we do hydraulic balancing.

52
00:03:17.600 --> 00:03:24.279
<v Chris Kopp>So if the installer sets that maximum flow
on every PICV that he puts into the

53
00:03:24.279 --> 00:03:30.809
<v Chris Kopp>hydraulic circuit, The system is already
balanced and it's much less effort to do it

54
00:03:30.809 --> 00:03:36.300
<v Chris Kopp>at this point in time than with
traditional valves to go back and do it basically

55
00:03:36.300 --> 00:03:42.059
<v Chris Kopp>when the total installation is finished,
and that's a big also time saving saving

56
00:03:42.059 --> 00:03:44.020
<v Chris Kopp>effort as we have seen in many projects.

57
00:03:45.279 --> 00:03:45.750
<v Jon Lester>Beautiful.

58
00:03:45.880 --> 00:03:46.320
<v Jon Lester>Thank you.

59
00:03:46.520 --> 00:03:51.960
<v Jon Lester>Uh, so we have the, the next, uh, word,
which is also a PICV related one, probably

60
00:03:51.960 --> 00:03:55.779
<v Jon Lester>on the other end of the scale to a certain
extent, a delta P min.

61
00:03:56.800 --> 00:04:03.759
<v Chris Kopp>Yes, so as the term says, pressure
independent refers to this differential

62
00:04:03.759 --> 00:04:09.960
<v Chris Kopp>pressure controller, which is a mechanical
setup within this complete control valve,

63
00:04:10.160 --> 00:04:15.960
<v Chris Kopp>and for this differential pressure
controller, it is necessary that the pump

64
00:04:15.960 --> 00:04:17.600
<v Chris Kopp>provides a minimum pressure.

65
00:04:18.070 --> 00:04:22.760
<v Chris Kopp>This is kind of the, the, the driving
force then of the differential pressure

66
00:04:22.760 --> 00:04:27.399
<v Chris Kopp>controller, and this is basically in
addition to the maximum flow that needs to be

67
00:04:27.399 --> 00:04:33.279
<v Chris Kopp>calculated and considered, is the other
key value that needs to be taken into

68
00:04:33.279 --> 00:04:38.339
<v Chris Kopp>consideration and the delta PMI is what we
have to make sure that it is always

69
00:04:38.809 --> 00:04:42.480
<v Chris Kopp>available at this PICV because then it
works properly.

70
00:04:42.559 --> 00:04:49.230
<v Chris Kopp>If the pump pressure puts less pressure on
the PICV, it basically, Defaults back to

71
00:04:49.230 --> 00:04:55.250
<v Chris Kopp>a standard normal or KVS valve, and then
you lose the benefits of this

72
00:04:55.540 --> 00:04:59.109
<v Chris Kopp>independence of the pressure situation
surrounding the valve.

73
00:04:59.790 --> 00:05:04.470
<v Jon Lester>So the Delta PMin is the minimum system
pressure that has to be applied at that

74
00:05:04.470 --> 00:05:08.579
<v Jon Lester>valve at that point in the system for it
to be able to operate as a pressure

75
00:05:08.579 --> 00:05:09.709
<v Jon Lester>independent control valve.

76
00:05:09.989 --> 00:05:11.649
<v Jon Lester>Absolutely beautiful.

77
00:05:12.029 --> 00:05:16.899
<v Jon Lester>So pressure independent control valves, we
just had a look at two of the key topics

78
00:05:16.899 --> 00:05:18.019
<v Jon Lester>that go along with that.

79
00:05:18.179 --> 00:05:22.760
<v Jon Lester>Let's look at the more traditional valves
that you mentioned before, a KVS valve.

80
00:05:23.660 --> 00:05:30.070
<v Chris Kopp>OK, so today we see more and more PICVs,
but that doesn't mean that the traditional

81
00:05:30.070 --> 00:05:36.709
<v Chris Kopp>KVS valves or standard globe control
valves or also ball control valves that work in

82
00:05:36.709 --> 00:05:39.459
<v Chris Kopp>this pattern are no longer needed.

83
00:05:39.549 --> 00:05:43.350
<v Chris Kopp>They still have their applications where
they are suitable and therefore it's

84
00:05:43.350 --> 00:05:43.690
<v Chris Kopp>important.

85
00:05:44.670 --> 00:05:51.660
<v Chris Kopp>To know what is a KVS valve, and KVS
basically stands for The maximum

86
00:05:51.660 --> 00:05:57.739
<v Chris Kopp>flow such a valve can handle under
predefined condition, and the predefined

87
00:05:57.739 --> 00:06:04.529
<v Chris Kopp>condition is that The KVS is a volumetric
flow in cubic meters per hour, and it

88
00:06:04.529 --> 00:06:11.380
<v Chris Kopp>is Defined at a pressure differential
across the valve of one bar

89
00:06:11.679 --> 00:06:14.559
<v Chris Kopp>or 100 kilopascal, so it's a

90
00:06:14.559 --> 00:06:20.079
<v Chris Kopp>clearly defined setting that helps then to
compare different valve types of products

91
00:06:20.079 --> 00:06:22.279
<v Chris Kopp>against each other and make the proper
selection.

92
00:06:23.709 --> 00:06:24.250
<v Jon Lester>Perfect.

93
00:06:25.029 --> 00:06:30.790
<v Jon Lester>Now let's have a look at a couple of key
terms or valve characteristics that we

94
00:06:30.790 --> 00:06:34.750
<v Jon Lester>might see with a KVS valve, similar to
what we did with the pressure independent

95
00:06:34.750 --> 00:06:38.130
<v Jon Lester>valve, V100.100.

96
00:06:38.549 --> 00:06:43.390
<v Chris Kopp>That's a term that you could also apply to
a PICB, but it's mainly used with KVS and

97
00:06:43.390 --> 00:06:49.679
<v Chris Kopp>it's, it's really the 100% volumetric
flow, you could say, and this is derived from

98
00:06:50.109 --> 00:06:55.179
<v Chris Kopp>The, the, the equation that considers the
power that we have to provide to a

99
00:06:55.179 --> 00:07:01.899
<v Chris Kopp>consumer and the decisive temperature
difference that is, is needed at this consumer

100
00:07:01.899 --> 00:07:08.380
<v Chris Kopp>and out of that we can figure out how much
water do we have to be able to

101
00:07:08.380 --> 00:07:13.880
<v Chris Kopp>handle with this valve, and that's what's
called V 100 for this KVS valve.

102
00:07:14.459 --> 00:07:15.299
<v Jon Lester>OK, beautiful.

103
00:07:17.130 --> 00:07:20.750
<v Jon Lester>Related to that to a certain extent, the
delta P V 100.

104
00:07:21.170 --> 00:07:27.609
<v Chris Kopp>Yes, as you said, it's related because it
also says V100, so it's the delta P, the

105
00:07:27.609 --> 00:07:34.489
<v Chris Kopp>pressure differential that we would like
to have at this valve when we have

106
00:07:34.489 --> 00:07:38.809
<v Chris Kopp>the nominal flow derived from the power
equation.

107
00:07:39.279 --> 00:07:46.160
<v Chris Kopp>And it's important that we consider that
with the KVS valves in order to reach

108
00:07:46.160 --> 00:07:48.079
<v Chris Kopp>a good controllability of the system.

109
00:07:50.230 --> 00:07:50.980
<v Jon Lester>Amazing.

110
00:07:51.359 --> 00:07:58.079
<v Jon Lester>Now one of the other parts that we see
when we're sizing KVS valves, one of the

111
00:07:58.079 --> 00:08:03.269
<v Jon Lester>important parts is to understand the valve
authority or the PV of that KVS valve.

112
00:08:03.320 --> 00:08:06.339
<v Jon Lester>Can you give us a bit of an insight into
the valve Authority?

113
00:08:06.679 --> 00:08:07.059
<v Jon Lester>Yes,

114
00:08:07.480 --> 00:08:14.359
<v Chris Kopp>so the Valve Authority P Index V is an
indicator of good

115
00:08:14.359 --> 00:08:15.820
<v Chris Kopp>controllability, you could say.

116
00:08:16.079 --> 00:08:22.750
<v Chris Kopp>And as a rule of thumb, We say it should
be 0.5 or a little bit higher,

117
00:08:22.950 --> 00:08:29.130
<v Chris Kopp>and in other terms it means that the
resistance across the valve that we basically

118
00:08:29.429 --> 00:08:35.570
<v Chris Kopp>put into this hydraulic circuit by
selecting the appropriate valve size.

119
00:08:36.679 --> 00:08:42.408
<v Chris Kopp>Has to relate to The part that the valve
wants to control, and this part we call

120
00:08:42.408 --> 00:08:49.398
<v Chris Kopp>delta PMV, and that's another term, but it
nicely fits now, it relates to that

121
00:08:49.398 --> 00:08:54.958
<v Chris Kopp>and it just means that the resistance
across the valve should be equal or greater

122
00:08:54.958 --> 00:09:00.158
<v Chris Kopp>than the resistance in the variable flow
part that is controlled by the valve, and

123
00:09:00.158 --> 00:09:02.289
<v Chris Kopp>this variable flow part is then called
delta PMV.

124
00:09:04.448 --> 00:09:07.408
<v Chris Kopp>And you might wonder what does MV stand
for.

125
00:09:07.700 --> 00:09:14.260
<v Chris Kopp>It comes out of certain standards and
norms, and it's derived from a German term.

126
00:09:14.500 --> 00:09:18.619
<v Chris Kopp>It's called Mengen variable, which in
English means variable flow part.

127
00:09:20.169 --> 00:09:21.270
<v Jon Lester>Perfect, thank you.

128
00:09:21.809 --> 00:09:25.520
<v Jon Lester>You mentioned just then variable flow, and
I think that's a really good time for us

129
00:09:25.520 --> 00:09:30.369
<v Jon Lester>to take a step back from the, the valves
as they are, the individual components

130
00:09:30.369 --> 00:09:32.010
<v Jon Lester>there and look a little bit more at the
system.

131
00:09:32.140 --> 00:09:35.270
<v Jon Lester>So what is variable volumetric flow?

132
00:09:35.979 --> 00:09:42.890
<v Chris Kopp>OK, so variable volumetric flow, I think
in today's situations is, is, is key

133
00:09:43.309 --> 00:09:50.190
<v Chris Kopp>because when we set up hydraulic circuits
from the producer across the distribution

134
00:09:50.190 --> 00:09:56.229
<v Chris Kopp>all the way out to the consumer, we really
want to have variable volumetric flow,

135
00:09:56.309 --> 00:10:01.669
<v Chris Kopp>meaning we only want to move as much water
as it is currently needed.

136
00:10:02.150 --> 00:10:07.590
<v Chris Kopp>Through our system with the pumps and if
we achieve that, then of course the whole

137
00:10:07.590 --> 00:10:14.000
<v Chris Kopp>system becomes more efficient because we
don't circulate unnecessary amounts of

138
00:10:14.000 --> 00:10:20.700
<v Chris Kopp>water which then needs a lot of electrical
power and also we don't have

139
00:10:21.000 --> 00:10:26.440
<v Chris Kopp>heat loss in case of a heating system or
heat gains into our network in case of a

140
00:10:26.440 --> 00:10:27.700
<v Chris Kopp>chilled water system.

141
00:10:28.000 --> 00:10:31.340
<v Chris Kopp>So volumetric flow is basically the
guiding.

142
00:10:31.640 --> 00:10:36.460
<v Chris Kopp>Idea when we set up a state of the art
hydraulic network.

143
00:10:37.330 --> 00:10:40.539
<v Jon Lester>And, and that volumetric flow or the
variable volumetric

144
00:10:40.539 --> 00:10:42.369
<v Chris Kopp>flow variable should should

145
00:10:42.369 --> 00:10:46.969
<v Jon Lester>be variable, and that's the comment I was
trying to make was that, uh, you know,

146
00:10:47.210 --> 00:10:53.159
<v Jon Lester>perhaps in a different time in our
industry or before variable flow volumetric flow

147
00:10:53.159 --> 00:10:58.890
<v Jon Lester>was, was consistent, this, this, um, you
know, the static volumetric flow or

148
00:10:58.890 --> 00:11:03.320
<v Jon Lester>consistent or constant variable, uh,
sorry, constant volumetric flow was the norm,

149
00:11:03.450 --> 00:11:03.780
<v Jon Lester>correct?

150
00:11:04.809 --> 00:11:11.429
<v Chris Kopp>Yes, it, it was often done this way or
used because it ensured that

151
00:11:11.729 --> 00:11:14.390
<v Chris Kopp>we had warm or cold water.

152
00:11:15.020 --> 00:11:21.830
<v Chris Kopp>Available out at The different consumers
whenever there was a need, but I

153
00:11:21.830 --> 00:11:27.330
<v Chris Kopp>think today that's less, less of a
critical topic because with modern building

154
00:11:27.330 --> 00:11:33.830
<v Chris Kopp>automation systems there is so much
information available that it's possible to

155
00:11:33.830 --> 00:11:40.669
<v Chris Kopp>derive and decide when do we need what
type of flow in which locations and you

156
00:11:40.669 --> 00:11:44.289
<v Chris Kopp>can handle it from there so it's no longer
necessary.

157
00:11:44.760 --> 00:11:50.250
<v Chris Kopp>To bring out, let's say, cold water to an
air handling unit that is at the other end

158
00:11:50.250 --> 00:11:55.750
<v Chris Kopp>of the building just to make sure that in
case cooling appears from the control side

159
00:11:56.130 --> 00:11:57.270
<v Chris Kopp>we are ready to go.

160
00:11:57.570 --> 00:12:04.460
<v Chris Kopp>We can achieve that today in most cases by
gathering information from The system

161
00:12:04.460 --> 00:12:09.539
<v Chris Kopp>set up and analyzing that in the building
automation system and then basically

162
00:12:09.539 --> 00:12:11.940
<v Chris Kopp>decide what needs to be done at any given
at any given time in the system,

163
00:12:14.719 --> 00:12:19.150
<v Jon Lester>right, so we're better at collecting
information and then we're more able to react

164
00:12:19.150 --> 00:12:25.179
<v Jon Lester>to that and make changes within the system
in enough time to be able to absorb those

165
00:12:25.179 --> 00:12:30.140
<v Jon Lester>requirements when they come along so that
we don't have to plan for and always

166
00:12:30.140 --> 00:12:32.520
<v Jon Lester>deliver the highest demand situation.

167
00:12:33.260 --> 00:12:34.419
<v Chris Kopp>Yes, exactly.

168
00:12:35.260 --> 00:12:35.979
<v Jon Lester>Beautiful.

169
00:12:36.479 --> 00:12:40.719
<v Jon Lester>Uh, so still looking at the system
perspective, maybe we'll zoom in just a little

170
00:12:40.719 --> 00:12:47.039
<v Jon Lester>bit to, to understand and look at a couple
of terms that we hear around the, the

171
00:12:47.039 --> 00:12:50.880
<v Jon Lester>different circuits and, and the
requirements.

172
00:12:50.919 --> 00:12:54.000
<v Jon Lester>It's something that you mentioned before,
and maybe the next word or phrase that

173
00:12:54.000 --> 00:12:57.450
<v Jon Lester>we'll look at is hydronic balancing
because that came into the discussion a little

174
00:12:57.450 --> 00:12:58.039
<v Jon Lester>bit earlier.

175
00:12:58.950 --> 00:13:05.159
<v Chris Kopp>Yes, uh, hydraulic balancing is a, is a
term that is often heard and, and, and also

176
00:13:05.159 --> 00:13:07.679
<v Chris Kopp>required in, in specifications and things
like that.

177
00:13:07.760 --> 00:13:14.719
<v Chris Kopp>But what we find unfortunately, it's very
often not done or not done properly

178
00:13:14.719 --> 00:13:20.250
<v Chris Kopp>because if you want to do it in a big
system, in a, in a proper way, It needs time

179
00:13:20.469 --> 00:13:26.950
<v Chris Kopp>and people are always crunched for time,
so that's one of the things that then is

180
00:13:26.950 --> 00:13:32.849
<v Chris Kopp>left out and people then just hope and
cross their fingers that, you know, we get

181
00:13:33.109 --> 00:13:36.590
<v Chris Kopp>enough warm water or enough cold water to
our consumers.

182
00:13:36.750 --> 00:13:43.619
<v Chris Kopp>And if that happens, nobody will make any
bad comments about it, but

183
00:13:44.179 --> 00:13:48.700
<v Chris Kopp>What we then find is very often we lose on
the energy efficiency side.

184
00:13:48.780 --> 00:13:53.179
<v Chris Kopp>So yes, the room gets warm, yes, the
chiller, the chilled water goes out to the air

185
00:13:53.179 --> 00:13:58.700
<v Chris Kopp>handling unit in a sufficient amount, but
it's not in the best energy efficient way.

186
00:13:58.739 --> 00:14:04.859
<v Chris Kopp>And that's why hydraulic balancing is an
important key part and it can be done in

187
00:14:04.859 --> 00:14:05.489
<v Chris Kopp>two ways.

188
00:14:05.659 --> 00:14:10.700
<v Chris Kopp>Traditionally it was done in a way that we
would call static hydraulic balancing,

189
00:14:10.780 --> 00:14:12.260
<v Chris Kopp>meaning setting.

190
00:14:12.510 --> 00:14:19.429
<v Chris Kopp>The maximum flow with a balancing, a
separate balancing valve at each consumer

191
00:14:19.429 --> 00:14:24.250
<v Chris Kopp>circuit and by that ensuring that they get
the proper amount of water.

192
00:14:24.669 --> 00:14:30.799
<v Chris Kopp>But because this is a one-time setting at
basically startup or

193
00:14:30.799 --> 00:14:32.510
<v Chris Kopp>initial installation.

194
00:14:33.099 --> 00:14:40.080
<v Chris Kopp>It is correct at this point of operation,
but we all know our systems are

195
00:14:40.080 --> 00:14:46.539
<v Chris Kopp>dynamic, and most of the time we have 50,
60, 70% of water that is

196
00:14:46.539 --> 00:14:53.380
<v Chris Kopp>needed, and then the static balancing
elements have some influence on the

197
00:14:53.380 --> 00:14:58.760
<v Chris Kopp>overall system behavior, and it can very
well be that all of a sudden some consumers

198
00:14:59.059 --> 00:15:02.559
<v Chris Kopp>get more water than They would like to
have, you

199
00:15:02.559 --> 00:15:08.880
<v Chris Kopp>can control that, but some other consumers
might get not enough water, and then we

200
00:15:08.880 --> 00:15:14.679
<v Chris Kopp>have a problem, and it has to do with the
dynamic behavior at different operating

201
00:15:14.679 --> 00:15:15.179
<v Chris Kopp>points.

202
00:15:15.719 --> 00:15:21.640
<v Chris Kopp>And because of this, the trend today is
moving towards what we would call dynamic

203
00:15:21.640 --> 00:15:22.919
<v Chris Kopp>hydraulic balancing.

204
00:15:23.150 --> 00:15:28.479
<v Chris Kopp>And this can be achieved, for example,
with the PICVs that we talked about before,

205
00:15:28.950 --> 00:15:34.190
<v Chris Kopp>because there you also set basically the
maximum flow comparable to the static

206
00:15:34.190 --> 00:15:40.450
<v Chris Kopp>balancing, but because now this PICV is
separated from

207
00:15:41.030 --> 00:15:45.669
<v Chris Kopp>the changes in the hydraulic network, the
pressure changes, and so on, we have a

208
00:15:45.669 --> 00:15:51.609
<v Chris Kopp>much more stable control, and that helps
to achieve.

209
00:15:52.119 --> 00:15:58.450
<v Chris Kopp>Balanced situations also during dynamic
situations, so you always have a balanced

210
00:15:58.450 --> 00:16:05.320
<v Chris Kopp>system then at 50% of load, at 70% of
load, and not only clearly and fully balanced

211
00:16:05.320 --> 00:16:11.799
<v Chris Kopp>at 100% of load like this was done and has
been with static balancing in the

212
00:16:11.799 --> 00:16:12.369
<v Chris Kopp>past.

213
00:16:12.760 --> 00:16:18.640
<v Chris Kopp>So here again, the trend is to move
towards hydraulic dynamic balancing.

214
00:16:19.080 --> 00:16:23.679
<v Chris Kopp>And this can be achieved, for example,
utilizing PICBs.

215
00:16:24.429 --> 00:16:31.349
<v Jon Lester>OK, so, so we used to use a single
snapshot, 100% load and 100%

216
00:16:31.349 --> 00:16:37.659
<v Jon Lester>demand to test to make sure that our
system operated as designed, but obviously as

217
00:16:37.659 --> 00:16:42.190
<v Jon Lester>soon as that situation changed, the demand
changed, the pressure within the system

218
00:16:42.190 --> 00:16:48.229
<v Jon Lester>changed because of that demand change, or
we used variable speed pumps or something

219
00:16:48.229 --> 00:16:53.349
<v Jon Lester>like this, then all of a sudden that
snapshot was not always accurate.

220
00:16:53.849 --> 00:16:54.830
<v Chris Kopp>Yes, exactly,

221
00:16:55.090 --> 00:16:59.239
<v Jon Lester>and this, and this dynamic approach means
that no matter what happens within the

222
00:16:59.239 --> 00:17:05.790
<v Jon Lester>system, we're able to deliver the expected
flow to those individual consumers

223
00:17:06.290 --> 00:17:07.640
<v Jon Lester>as they've been designed.

224
00:17:07.989 --> 00:17:14.410
<v Chris Kopp>Yeah, exactly, because then the cross
influence that can happen amongst consumers is

225
00:17:14.410 --> 00:17:15.329
<v Chris Kopp>eliminated.

226
00:17:16.790 --> 00:17:17.290
<v Jon Lester>Perfect.

227
00:17:18.300 --> 00:17:20.819
<v Jon Lester>So let's have a look at a couple of
different circuits because we've talked about

228
00:17:20.819 --> 00:17:21.300
<v Jon Lester>valves.

229
00:17:21.359 --> 00:17:26.199
<v Jon Lester>We've talked now a little bit about the
system, but the circuit itself is, is really

230
00:17:26.199 --> 00:17:29.099
<v Jon Lester>the, the all encompassing part of this
individual consumer.

231
00:17:29.219 --> 00:17:34.810
<v Jon Lester>So the not just the valve itself, but the,
you know, the, the coils and any other

232
00:17:34.810 --> 00:17:40.040
<v Jon Lester>actual temperature or energy delivery
device into the airflow, etc.

233
00:17:40.979 --> 00:17:46.060
<v Jon Lester>We have Two different circuits here on my
list, so we'll go one at a time, and you

234
00:17:46.060 --> 00:17:47.660
<v Jon Lester>could give us a little bit of an
explanation.

235
00:17:47.739 --> 00:17:48.339
<v Jon Lester>That would be great.

236
00:17:48.459 --> 00:17:50.900
<v Jon Lester>So the first I have is throttling circuit.

237
00:17:51.930 --> 00:17:57.329
<v Chris Kopp>Yes, so a throttling circuit basically the
term says exactly what it's doing.

238
00:17:57.810 --> 00:18:04.760
<v Chris Kopp>You have a valve in a pipe and it just
shuts off or lowers the flow by closing

239
00:18:04.760 --> 00:18:11.270
<v Chris Kopp>off, so it throttles the flow in this
entire circuit, and we use that a lot

240
00:18:11.270 --> 00:18:17.310
<v Chris Kopp>in situations where we want to supply a
variable flow to the consumer.

241
00:18:17.810 --> 00:18:24.650
<v Chris Kopp>And we want to ensure that we always get
the same supply temperature to this

242
00:18:24.650 --> 00:18:25.280
<v Chris Kopp>consumer.

243
00:18:25.770 --> 00:18:31.790
<v Chris Kopp>A good example for that is in a chilled
water situation when you have to provide

244
00:18:32.449 --> 00:18:37.449
<v Chris Kopp>cold water to a cooling coil, not only for
cooling the air but also for

245
00:18:37.449 --> 00:18:39.189
<v Chris Kopp>dehumidification of the air.

246
00:18:39.660 --> 00:18:45.500
<v Chris Kopp>Then we have to make sure we always get
really very cold water, more or less from

247
00:18:45.500 --> 00:18:50.239
<v Chris Kopp>the flow part to that coil in order to
make the dehumidification happen.

248
00:18:50.540 --> 00:18:57.020
<v Chris Kopp>And so the throttling circuit is, is a
proven circuit to use in situations where we

249
00:18:57.020 --> 00:19:03.599
<v Chris Kopp>want to have variable flow, but always a
steady supply temperature to our consumer.

250
00:19:04.239 --> 00:19:10.969
<v Chris Kopp>And it also is a good, Circuit to utilize
the PICVs that we

251
00:19:10.969 --> 00:19:17.589
<v Chris Kopp>talked about before, because the PICVs in
general are two port valves, and

252
00:19:17.969 --> 00:19:22.670
<v Chris Kopp>because we just put a valve into one pipe,
a two port valve is sufficient.

253
00:19:23.790 --> 00:19:26.859
<v Jon Lester>Yeah, that was the perfect summary, I
think so.

254
00:19:27.689 --> 00:19:33.609
<v Jon Lester>A valve to deliver the same supply
temperature but to regulate the flow.

255
00:19:34.369 --> 00:19:39.089
<v Jon Lester>Yes, yes, and the next one I had was
injection circuit, which I'm having a guess

256
00:19:39.089 --> 00:19:42.410
<v Jon Lester>here is perhaps the other way around to a
certain extent.

257
00:19:43.329 --> 00:19:47.359
<v Chris Kopp>Yeah, it's a little bit of a different
setup and, and when we talk about the

258
00:19:47.359 --> 00:19:50.810
<v Chris Kopp>injection circuit, we have to
differentiate it.

259
00:19:50.849 --> 00:19:57.660
<v Chris Kopp>Is it An injection circuit with a 2 port
valve or a 3 port valve, and

260
00:19:58.030 --> 00:20:03.839
<v Chris Kopp>to be honest with you, my hope is that a
couple of years from now when somebody says

261
00:20:03.839 --> 00:20:10.619
<v Chris Kopp>injection circuit, it is clear it's one
with a 2 port valve because this setup is

262
00:20:10.920 --> 00:20:17.359
<v Chris Kopp>the energy efficient setup because the
injection circuit provides a constant flow

263
00:20:17.359 --> 00:20:18.540
<v Chris Kopp>across the consumer.

264
00:20:18.939 --> 00:20:25.699
<v Chris Kopp>And controls the power or the capacity
with changing the temperature spread and

265
00:20:25.699 --> 00:20:31.579
<v Chris Kopp>adjusting the temperature difference is
done by injecting in a heating circuit, for

266
00:20:31.579 --> 00:20:37.540
<v Chris Kopp>example, more or less hot water from the
production side into the continuous

267
00:20:38.300 --> 00:20:44.989
<v Chris Kopp>circulating water stream across the
consumer and The two port valve is

268
00:20:44.989 --> 00:20:48.589
<v Chris Kopp>then in the supply line from the
production

269
00:20:48.589 --> 00:20:55.310
<v Chris Kopp>side, which means there again we are with
variable flow in the long pipes from the

270
00:20:55.310 --> 00:20:57.770
<v Chris Kopp>production all the way out to our
consumer.

271
00:20:58.020 --> 00:21:03.069
<v Chris Kopp>And so that's again a situation that we
want to see more and more in the future.

272
00:21:03.900 --> 00:21:08.180
<v Chris Kopp>Either throttling circuits as discussed
before, or then injection circuits with two

273
00:21:08.180 --> 00:21:08.989
<v Chris Kopp>port valves.

274
00:21:10.140 --> 00:21:15.660
<v Jon Lester>And these two circuits by using 2 port
valves, these are the preferred approach

275
00:21:15.660 --> 00:21:20.939
<v Jon Lester>because if we use a 3 port valve, we're
pumping water around in circles for no

276
00:21:20.939 --> 00:21:21.560
<v Jon Lester>particular reason.

277
00:21:21.589 --> 00:21:22.300
<v Jon Lester>Is that correct?

278
00:21:23.180 --> 00:21:26.699
<v Chris Kopp>It's correct in certain applications.

279
00:21:26.780 --> 00:21:32.979
<v Chris Kopp>So that's why, for example, the diverting
circuit and the injection circuit with 3

280
00:21:32.979 --> 00:21:36.579
<v Chris Kopp>port valves, they should go away, right?

281
00:21:36.810 --> 00:21:42.310
<v Chris Kopp>I, I don't like to see them anymore in, in
new, in new plannings for sure not.

282
00:21:42.540 --> 00:21:48.219
<v Chris Kopp>And also in existing situations, people
should really think about to convert them to

283
00:21:48.219 --> 00:21:52.739
<v Chris Kopp>throttling or injection circuits with two
port valves, which, which is very easy.

284
00:21:53.119 --> 00:21:58.839
<v Chris Kopp>The, the, the mixing valve, the 3 port
valve still has its applications with the

285
00:21:58.839 --> 00:22:00.520
<v Chris Kopp>traditional mixing circuits.

286
00:22:00.560 --> 00:22:06.219
<v Chris Kopp>There, it still makes still a lot of sense
in, in typical, let's say, heating

287
00:22:06.219 --> 00:22:11.160
<v Chris Kopp>applications where you have your
distribution and your consumer circuits in the

288
00:22:11.160 --> 00:22:15.400
<v Chris Kopp>boiler room, in the heating plant room,
there they are still applicable, and they

289
00:22:15.400 --> 00:22:18.859
<v Chris Kopp>are also energy efficient under these
considerations.

290
00:22:19.780 --> 00:22:21.319
<v Jon Lester>OK, perfect, thank you.

291
00:22:21.900 --> 00:22:27.400
<v Jon Lester>Um, so let's get away from the circuits
now, the next, The term that I have on the

292
00:22:27.400 --> 00:22:30.699
<v Jon Lester>list is proportional laws and affinity
laws.

293
00:22:31.630 --> 00:22:33.369
<v Jon Lester>Could you give us some insight into those?

294
00:22:34.130 --> 00:22:38.829
<v Chris Kopp>Yes, so proportional laws, as we, let's
say, call it more.

295
00:22:39.510 --> 00:22:45.430
<v Chris Kopp>In the German speaking countries or let's
say in Europe, or affinity laws as they

296
00:22:45.430 --> 00:22:52.189
<v Chris Kopp>are called in English speaking countries
are basically laws that are derived from

297
00:22:52.189 --> 00:22:56.109
<v Chris Kopp>the fluid dynamics theory, and these laws
apply.

298
00:22:56.689 --> 00:23:03.329
<v Chris Kopp>To our hydraulic setups, meaning our
water-based circuits for heating and cooling,

299
00:23:03.520 --> 00:23:08.810
<v Chris Kopp>but they also apply in the same manner to
our airstreams in the ductwork.

300
00:23:09.089 --> 00:23:16.010
<v Chris Kopp>So these fluid dynamics laws we, we can
apply with the medium that we

301
00:23:16.010 --> 00:23:18.770
<v Chris Kopp>normally work with, either water, cold or
warm.

302
00:23:19.449 --> 00:23:24.760
<v Chris Kopp>Or then with the air that we run through
the building, and they are very important

303
00:23:24.760 --> 00:23:31.640
<v Chris Kopp>because they have a big impact on energy
efficiency and The, let's say the main

304
00:23:31.640 --> 00:23:37.719
<v Chris Kopp>one or the key one is the proportional law
number 2 or the second one, because it

305
00:23:37.719 --> 00:23:44.380
<v Chris Kopp>defines that the resistance in our
hydraulic network changes

306
00:23:44.920 --> 00:23:48.619
<v Chris Kopp>not directly proportional, but it changes
by the square

307
00:23:48.880 --> 00:23:53.920
<v Chris Kopp>compared to the volume flow that we run
through this network, which I think is very

308
00:23:53.920 --> 00:24:00.810
<v Chris Kopp>obvious that If you only run, for example,
half the volumetric flow to a

309
00:24:00.979 --> 00:24:04.489
<v Chris Kopp>pipe that was designed to handle 100% of
this flow.

310
00:24:05.310 --> 00:24:10.349
<v Chris Kopp>The resistance that you get on the walls
of these pipes or so goes back rather

311
00:24:10.349 --> 00:24:15.920
<v Chris Kopp>drastically because your flow speed is
much slower and you have a lot less

312
00:24:15.920 --> 00:24:22.729
<v Chris Kopp>resistance and the fluid dynamics theory
says that this resistance goes down by the

313
00:24:22.729 --> 00:24:23.369
<v Chris Kopp>square.

314
00:24:23.550 --> 00:24:29.739
<v Chris Kopp>So for After the flow, it means we only
have to overcome a 25% of the

315
00:24:29.739 --> 00:24:35.310
<v Chris Kopp>resistance that we had to overcome at the
design conditions, and that of course is a

316
00:24:35.310 --> 00:24:41.630
<v Chris Kopp>big change and it is a very, let's say,
fundamental law in our hydraulic

317
00:24:41.630 --> 00:24:48.469
<v Chris Kopp>circuits because then based on that, Also,
the power consumption goes down

318
00:24:48.569 --> 00:24:53.250
<v Chris Kopp>dramatically, and here the theory says it
goes down by the power of

319
00:24:53.250 --> 00:24:59.689
<v Chris Kopp>3, which is a little bit too optimistic,
but in a lot of cases it goes down

320
00:24:59.689 --> 00:25:06.170
<v Chris Kopp>dramatically by more than the square or
close to to the power of 3, so.

321
00:25:06.564 --> 00:25:11.545
<v Chris Kopp>That's why we, we should really focus on
these proportional laws, and they are

322
00:25:11.545 --> 00:25:17.555
<v Chris Kopp>basically the reasons why we have variable
speed drives, why we have EC motors and

323
00:25:17.555 --> 00:25:24.165
<v Chris Kopp>pumps and fans that we can then control
the speed to, to really work with these laws

324
00:25:24.165 --> 00:25:26.974
<v Chris Kopp>and, and get as much as possible out of
it.

325
00:25:27.435 --> 00:25:28.395
<v Jon Lester>OK, perfect.

326
00:25:29.300 --> 00:25:30.209
<v Jon Lester>Chris, thank you so much.

327
00:25:30.260 --> 00:25:36.459
<v Jon Lester>We've covered a huge amount of different
terms, whether they're part of choosing,

328
00:25:36.739 --> 00:25:41.579
<v Jon Lester>selecting, and ensuring that we understand
correctly the valves that we're putting

329
00:25:41.579 --> 00:25:47.180
<v Jon Lester>within the system, the circuits that help
make up that system, or the system itself,

330
00:25:47.339 --> 00:25:53.530
<v Jon Lester>how we describe it, and how we look at the
way that we control the flow and the

331
00:25:53.530 --> 00:25:57.699
<v Jon Lester>different approaches that we have in
controlling the pumps that deliver that flow

332
00:25:57.699 --> 00:25:58.339
<v Jon Lester>and that pressure.

333
00:25:58.880 --> 00:26:01.569
<v Jon Lester>Thank you so much as always for joining
us.

334
00:26:01.969 --> 00:26:04.479
<v Jon Lester>Um, we very much enjoy it when you visit
me.

335
00:26:04.530 --> 00:26:08.489
<v Jon Lester>I, I get the feeling that we probably have
another one of these buzzword busters in

336
00:26:08.489 --> 00:26:14.920
<v Jon Lester>us when we want to talk about other
components of, of the, uh, of the HVAC systems.

337
00:26:15.290 --> 00:26:15.359
<v Jon Lester>Yeah,

338
00:26:15.410 --> 00:26:17.869
<v Chris Kopp>I think there is more to discuss or

339
00:26:17.869 --> 00:26:19.869
<v Jon Lester>another good buzz buzzword buster for
sure.

340
00:26:20.770 --> 00:26:21.890
<v Jon Lester>So thank you, thank you.

341
00:26:22.135 --> 00:26:27.165
<v Jon Lester>Chris, uh, and thank you to all of you out
there for listening to this episode.

342
00:26:27.324 --> 00:26:30.125
<v Jon Lester>Please feel free to share, like and
comment on this episode.

343
00:26:30.244 --> 00:26:33.525
<v Jon Lester>Subscribe to us on whichever channel
you're listening to us right now.

344
00:26:34.114 --> 00:26:34.895
<v Jon Lester>Uh remember to share.

345
00:26:35.385 --> 00:26:40.005
<v Jon Lester>Uh, and as always, we very much appreciate
your time in joining us, and we look

346
00:26:40.005 --> 00:26:41.204
<v Jon Lester>forward to seeing you again soon.

347
00:26:41.464 --> 00:26:41.944